Dimension: 3.500 Inch Length x 1.500 Inch Width
Safely loaded to 100% of stated capacity
1 Watt minimum load
All connections must be made in an enclosure for proper installations
Dimmable with electronic low voltage dimmers, dimmers should always be installed on the primary side of the transformer
The soft start delayed start feature extends lamp life by delaying the abrupt inrush current to the lamp
Detailed Description: WAC Lighting Low Voltage Non enclosed electronic transformer in black color is used as replacement part for factory installed transformers. It has a input voltage rating of 120 Volts and output voltage rating of 12 Volts. It has a power rating ranging from 35 - 100 Watts. It features built-in auto reset, overload, soft start and short circuit protection technologies. System protection is designed to lost for several hours. It measures 3.500 Inch x 1.500 Inch. It includes multiple terminal block that can accommodate 6 output connections for 14 AWG wires. Electronic transformer is UL listed.
Application | For To Be Used As A Replacement Part For Factory Installed Transformers |
Brand | WAC Lighting |
Catalog Description | Wac Lighting EN-12100-R-AR Electronic Transformer, Low Voltage, Non-Enclosed, EN-12150-RB-AR, 120 V Input, 12 V Output, 35 - 100 WTT, 20 KHZ, Black, 3-1/2 IN Length, 1-1/2 IN Width, 1-1/4 IN Height, Polycarbonate, Aluminum, 0.83 AMP At 120 V Maximum Input Amperage, UL E204239, 2108 Listed, Used As A Replacement Part For Factory Installed Transformers |
Country Of Origin | US |
Finish 2 | Black |
Frequency Rating | 20 Kilo Hz |
GTIN |
00790576094632 |
Height | 1-1/4 Inch |
Input Voltage | 120 Volt |
Item | Electronic Transformer |
Length | 3-1/2 Inch |
Mfr. # | EN-12100-R-AR |
Model | EN-12150-RB-AR |
Output Voltage | 12/24 Volt |
Power Rating | 100 VA |
Special Features | Transformer may be safely loaded to 100 PCT of stated capacity ; Built-in auto reset, soft start, short and overload circuit protection features ; Soft start delayed start feature extends lamp life ; Dimmable with electronic low voltage dimmers, dimmers should always be installed on the primary side of the transformer ; In the case of a system overload or short circuit the transformer will revert to a ôholdö position and then automatically reset the system when the problem is solved ; System protection is designed to last several hours ; All connections must be made in an enclosure for proper installations ; True RMS meter is required to read the high frequency output ; Accessories: ETB û enclosure and connection box, MTB-01 û terminal block, 5 YR product warranty |
Standard | UL E204239, 2108 Listed |
Standards | UL Listed |
Type | Non-Enclosed |
Wattage | 35 - 100 |
Width | 1-1/2 Inch |