GE Distribution TL412C PowerMark Gold™ Standard Main Lug Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 4, 1/2 Inch: 2, 4, 42, 8 Space, 8 Circuit, 3-Wire, Flush/Surface

  • ABB TL412C GE Distribution TL412C PowerMark Gold™ Standard Main Lug Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 4, 1/2 Inch: 2, 4, 42, 8 Space, 8 Circuit, 3-Wire, Flush/Surface
  • GE Distribution TL412C PowerMark Gold™ Standard Main Lug Load Center; 125 Amp, 120/240 Volt AC, 1 Phase, 1 Inch: 4, 1/2 Inch: 2, 4, 42, 8 Space, 8 Circuit, 3-Wire, Flush/Surface
Manufacturer: ABB
Mfr. #: TL412C
Item #: 112379
UPC: 783164208306
This item cannot be purchased online. Please contact your local branch.

Product Details

Size: 8.630 Inch Width x 3.050 Inch Depth x 10.380 Inch Height

One piece interior removes and reinstalls easily

Full-length neutrals are easier to wire,2 reducing installation time and cost

Minimum 100% neutral terminations

Combination slotted/robertson square-drive speeds screw wiring

All holes rated for 14-4 wire

100% rated split neutral on each side

Tie bar may be removed to split neutral/ground

Detailed Description: GE Distribution PowerMark Gold™ 1-Phase 3-Wire Standard load center has THQL/THQP type main breaker for added safety and protection. It has voltage rating of 120/240 VAC and current rating of 125 Amps. It has interrupting capacity rating of 10 kilo-Amps. Load center has eight circuits, four spacing of 1-Inch and 2/4/42/8 spacing of 1/2-Inch for convenient operation. It has top/bottom feed for convenience. Load center has four spaces for 1-Pole/1-Inch THQL breakers and two spaces for 2-Pole/1-Inch. It has eight spaces for 1-Pole, 1/2-Inch THQP breakers and three spaces for 2-Pole, 1/2-Inch THQP breakers. It can accommodate aluminum/copper wires of size 1 - 2/0 AWG. Load center has combination flush/surface cover to improve aesthetic look.

Main lug load center has conductor temperature rating of 60/75 deg C. It has NEMA 1 indoor enclosure to provide protection against dust, light and indirect splashing. Load center can be used as service entrance equipment when installed under the guidance of NEC and has RMS symmetrical rating of 22 kAIC. It has plug-in breaker mounting for easy installation. It measures 8.630 Inch x 3.050 Inch x 10.380 Inch. Load center is UL listed and GSA complaint.

Product Specification

Amperage Rating 125 A
Brand GE
Catalog Description Panelboards No. 67 60 degree/75 degree centrigrade Conductor Rating Suitable for use as service entrance equipment when Installed in accordance with the National Electrical Code 22kAIC RMS symmetrical, Except Where Noted 6-42 circuit devices UL Listed for bottom mounted lugs by installing complete unit (box, interior and front) upside down For a listing of CSA Listed load centers, visit www.geelectrical.com Amperage 125 A 412C8306
Enclosure Indoor
GTIN

00783164208306

Height 3.7500
Height Unit IN
Interrupt Rating 10
Item Status A
Length 10.5000
Length UOM IN
Load Regulation 120/240V ac
Mfr. # TL412C
Mounting 0
Number Of Feeders Either
Phase 1 Phase
Special Features "Main lug load centers can be used as a home's main panel or sub panel depending upon your preferences. All ABB load centers are rated up to 60 degree/75 degree centrigrade and is suitable for use with service entrance equipment when installed in accordance with electrical code. The TL412C features space for 4, 1"" breakers, a 125 A bus ampere rating, and a combination/flush enclosure."
Standard UL
Type Standard
UNSPSC 39121101
Width 9.0000
Width UOM IN
Wiring Configuration 3 Wire