Sign in or register to view your pricing and inventory.

Square D ATS01N125FT Stop Unit Soft Starter, 24 VAC Control Circuit, 24 A, IP20, 1-Phase

Manufacturer: Square D by Schneider Electric
Mfr. #: ATS01N125FT
Item #: 247659
UPC: 785901167655
Login for Availability
Your Price:

Product Details

These control one phase of the motor power supply to limit the starting torque

They feature an internal bypass relay

Detailed Description: Square D by Schneider Electric Altistart 01 soft starter operates either as a torque limiter on starting, or as a soft start/soft stop unit for asynchronous motors. Using the Altistart 01 starter enhances the starting performance of asynchronous motors by allowing them to start gradually, smoothly, and in a controlled manner. It helps to prevent mechanical shocks, which cause wear and tear, and subsequent maintenance work and production downtime. The Altistart U01 limits the starting torque and current peaks on starting on machines that do not require a high starting torque.

Product Specification

Amperage Rating 125 A AT NOMINAL LOAD
Application ASYNCHRONOUS MOTORS,SIMPLE MACHINE
Brand ALTISTART 01
Catalog Description Schneider Electric,SOFT STARTER 25A 110 48V
Connection 4 MM SCREW CLAMP TERMINAL - RIGID 1 1...10 MMA AWG 8 POWER CIRCUIT-SCREW CONNECTOR - FLEXIBLE WITHOUT CABLE END 2 0.5...1.5 MMA AWG 16 CONTROL CIRCUIT-SCREW CONNECTOR - RIGID 1 0.5...2.5 MMA AWG 14 CONTROL CIRCUIT-4 MM SCREW CLAMP TERMINAL - RIGID 2 1...6 MMA AWG 10 POWER CIRCUIT-SCREW CONNECTOR - RIGID 2 0.5...1 MMA AWG 17 CONTROL CIRCUIT-SCREW CONNECTOR - FLEXIBLE WITH CABLE END 1 0.5...1.5 MMA AWG 16 CONTROL CIRCUIT-4 MM SCREW CLAMP TERMINAL - FLEXIBLE WITHOUT CABLE END 1 1.5...10 MMA AWG 8 POWER CIRCUIT-SCREW CONNECTOR - FLEXIBLE WITHOUT CABLE END 1 0.5...2.5 MMA AWG 14 CONTROL CIRCUIT-4 MM SCREW CLAMP TERMINAL - FLEXIBLE WITH CABLE END 2 1...6 MMA AWG 10 POWER CIRCUIT-4 MM SCREW CLAMP TERMINAL - FLEXIBLE WITHOUT CABLE END 2 1.5...6 MMA AWG 10 POWER CIRCUIT
GTIN

00785901167655

Item Status A
Mfr. # ATS01N125FT
Motor Power 11 HP, 3 PHASE 460 V-2 HP, 3 PHASE 210 V-3 HP, 3 PHASE 210 V-5 HP, 3 PHASE 230 V-9 HP, 3 PHASE 460 V-7.5 HP, 3 PHASE 230 V,11 KW, 3 PHASE 400 V-3 KW, 3 PHASE 230 V-4 KW, 3 PHASE 230 V-9 KW, 3 PHASE 400 V-7.5 KW, 3 PHASE 400 V-5.5 KW, 3 PHASE 230 V-2.2 KW, 1 PHASE 230 V
Operating Temperature -10-40 AC WITHOUT)-40-50 AC WITH CURRENT DERATING OF 2 PER AC)
Phase 1
Power Supply 110...480 V - 10...10 ,50...60 HZ - 5...5
Size 5.16
Special Features INTEGRATED BYPASS,START WITH VOLTAGE RAMP,WITH HEAT SINK
Standard 1 GN 13-150 HZ)EN/IEC 60068-2-6-1.5 MM PEAK TO PEAK 3-13 HZ)EN/IEC 60068-2-6,15 GN 11 MS EN/IEC 60068-2-27,B44.1-96/ASME A17.5 FOR STARTER WIRED TO THE MOTOR DELTA TERMINAL-C-TICK-CCC-GOST-CSA-UL,CE,EN/IEC 60947-4-2,IP20,CONDUCTED AND RADIATED EMISSIONS LEVEL B CISPR 11-IMMUNITY TO ELECTRICAL TRANSIENTS LEVEL 4 IEC 61000-4-4-IMMUNITY TO RADIATED RADIO-ELECTRICAL INTERFERENCE LEVEL 3 IEC 61000-4-3-MICRO-CUTS AND VOLTAGE FLUCTUATION IEC 61000-4-11-VOLTAGE/CURRENT IMPULSE LEVEL 3 IEC 61000-4-5-CONDUCTED AND RADIATED EMISSIONS LEVEL B IEC 60947-4-2-DAMPED OSCILLATING WAVES LEVEL 3 IEC 61000-4-12-ELECTROSTATIC DISCHARGE LEVEL 3 IEC 61000-4-2-EMC IMMUNITY EN 50082-1-EMC IMMUNITY EN 50082-2-HARMONICS IEC 1000-3-2-HARMONICS IEC 1000-3-4-IMMUNITY TO CONDUCTED INTERFERENCE CAUSED BY RADIO-ELECTRICAL FIELDS LEVEL 3 IEC 61000-4-6
Type ATS01;Soft starter
UNSPSC 39121521
Voltage Rating <= POWER SUPPLY VOLTAGE
Wattage 1 W AT FULL LOAD AND AT END OF STARTING-126 W IN TRANSIENT STATE