Dimension: 18 Inch Length x 1 Inch Width
Hi-lume 3D ballasts deliver high dimming ratios and efficiency in a slim-profile enclosure, making it a great choice for low-profile architectural fixtures
Because Hi-lume 3D is microprocessor-controlled, it can operate on the EcoSytem digital control bus and has the ability to listen, think, decide and remember, this provides a new level of flexibility in configuring lighting while saving energy
Programmed rapid start design preheats lamp cathodes before applying full arc voltage to enhance lamp life
Frequency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 42 kHz
Ultra-quiet operation
Factory-tuned ballasts with a custom ballast factor lower than standard models are available, and can be selected by utilizing the ballast selection tool
Lamp current Crest factor is less than 1.7
Detailed Description:
Lutron Hi-Lume® 3D Electronic dimming ballast has a voltage rating of 120/240/277 Volts. Ballast is compatible with T8, U bent lamps and can operate two lamps of power rating 32 Watts. A-rated ballast operates silently and has a ballast factor of 1. Energy efficient ballast incorporates inrush current limiting circuitry to prevent circuit breaker tripping, switch arcing and relay failure. It features programmed starting method that ensures long lamp life.
Dimming ballast provides uniform lighting and is ideal for all industrial applications. Ballast features flicker-free dimming from 100% to 0.7% for T8 lamps. Ballast offers wide range of dimming level without going to full brightness. It has very low harmonic distortion throughout the entire dimming range and maintains consistent light output for different lamp lengths. The case has a temperature rating 75 deg C. Ballast is grounded by a mounting screw to the fixture. Ballast has high power factor greater than 0.95. It measures 18 Inch x 1 Inch. Ballast is UL listed and CSA certified.
Amperage Rating | [email protected] V/[email protected]/[email protected] |
Application | Lighting Control |
Ballast Factor | 1 |
Brand | Lutron |
Catalog Description | Hi-lume 3D 1 percent 3-Wire and EcoSystem Digital Link Controlled T8 Linear and U-Bent, 2 lamps, ballast factor of 1.00, C-can, 32W |
Finish 2 | White |
Frequency Rating | 50/60 |
GTIN |
00027557775335 |
Height | 1 |
Height Unit | IN |
Item Status | A |
Lamp Type | T8/U-Bend fluorescent |
Length | 18 |
Length UOM | IN |
Mfr. # | H3DT832CU210 |
Minimum Starting Temperature | 50 |
Mounting | Fixture |
Number Of Lamps | 2 |
Power Factor | Greater than or equal to 0.95 |
Special Features | Designed to meet the most demanding lighting requirements. By providing industry leading performance with a full-range of 100 % to 0.7 % continuous, flicker-free fluorescent dimming, Hi-lume 3D ballasts enable you to provide the ideal visual environment for any application. 100% compatible with all Lutron 3-wire fluorescent and EcoSystem digital controls for consistent fixture-to-fixture dimming performance. Compatible with Energi Savr Node with EcoSystem devices, GRAFIK Eye QS control units, PowPak dimming modules with EcoSystem connection, and Quantum software, allowing for integration into an existing or planned EcoSystem lighting control solution. Programmed rapid-start design preheats lamp cathodes before applying full arc voltage to ensure full-rated lamp life while dimming and cycling. Lamps turn on to any dimmed level without going to full brightness. Low harmonic distortions throughout the entire dimming range maintains power quality. Frequency of operation ensures that ballast does not interfere with infrared devices operating between 38 and 42 kHz. Inrush current limiting circuitry eliminates circuit breaker tripping, switch arcing, and relay failure. Ballasts maintain consistent light output for different lamp lengths, ensuring fixture-to-fixture uniformity. Ultra-quiet operation. Ballast protected from miswires of any input power to control lead, or from lamp leads to each other and/or ground. 100 % performance-tested and burned-in at factory. Non-volatile memory restores all ballast settings after power failure. Custom ballast factors available for UL or CSA-listed products. Design tool and specifications can be found at www.lutron.com/ballasttool. |
Standard | UL, CSA, Class P thermal protected, ANSI, FCC |
Start Type | Programmed rapid |
Sub-Brand | Hi-lume 3D |
Thermal Protection | Class P |
Total Harmonic Distortion | Less than or equal to 10% |
Type | Ballast |
UNSPSC | 39101901 |
Voltage Rating | 120/240/277 |
Wattage | 32 |
Width | 1.18 |
Width UOM | IN |