Provides industry's most flexible modular sensor family, with over 5,000 custom configurations
Offers interchangeable ac or dc power blocks and choice of 2, 3 or 4-wire sensor blocks
Ranges to 200 m
Offers choice of output timing logic modules for output timing control
Features ambient light receivers, optical edge transmitters and optical edge guides for specialized applications
Add 8.3 ms to the OFF-time response of the scanner block
Detailed Description: Banner 4-Wire Photoelectric sensor is designed for use with MULTI-BEAM sensors. Power block sensor is rated at 105 - 130 Volts and has frequency rating of 50/60 Hz. It is made of thermoplastic for durability and majorly used for AC operation. It has maximum switching capacity of 750 milli-Amps at 250 VAC. Sensor handles the inrush current of AC inductive loads like motor starters and solenoids. It interfaces directly to all AC programmable controller inputs. SPST output sensor features built-in transient suppression to avoid false turn-on or damage from inductive loads and line spikes. Outputs of multiple power blocks can be wired in series or parallel for "AND" and "OR" logic functions. Sensor UL and CSA listed.
Amperage Rating | 0.75 Amp |
Application | For Multi-Beam Sensors |
Brand | Banner |
Catalog Description | Banner Power Block,105 - 130 VAC,50/60 HZ,Mounting: Wiring Chamber,Output: SPST Solid-State SCR (N.O.), 3/4 AMP Maximum (Derated to 1/2 AMP at 70 DEG C) Maximum Inrush: 10 AMP for 1 S or 30 AMP for 1 AC Cycle (Non-Repeating) On-state Voltage Drop: Less |
Connection | Terminal |
Country Of Origin | USA |
Frequency Rating | 50/60 |
GTIN |
00662488163846 |
Item | AC Power Block |
Material | Thermoplastic |
Mfr. # | PBA |
Mounting | Wiring Chamber |
Special Features | Most commonly used for AC operation; Range depends on sensor; 4-Wire operation; The output is rated for 250V AC maximum, and all can switch a voltage which is different than the supply as long as both AC circuits share a common neutral; Designed to handle the inrush current of AC inductive loads like motor starters and solenoids and the "holding current" specification of any inductive load should not exceed the 750 MILAMP output rating; Will interface directly to all AC programmable controller inputs; Contain built-in transient suppression to prevent false turn-on or damage from inductive loads and line "spikes"; Outputs of multiple power blocks may be wired in series or parallel for "AND" and "OR" logic functions |
Standard | UL And CSA Listed |
Standards | UL Listed, CSA Certified |
Type | 3 And 4-Wire |
Voltage Rating | 105 - 130 Volt |